Eaton PDUMV20HVNETLX PDU - Tripp Lite by 3.7kW Single Phase Switched LX Interface 208/230V Outlets (20 C13 & 4 C19) C20/L6 20P 0U TAA Switched NEMA L6 20P, IEC 60320 C20 4 x IEC 60320 C19, 20 x IEC 60320 C13 230 V AC 0U Vertical Rack Mount TAA C
Eaton PDUMV20HVNETLX PDU - Tripp Lite by 3.7kW Single Phase Switched LX Interface 208/230V Outlets (20 C13 & 4 C19) C20/L6 20P 0U TAA Switched NEMA L6 20P, IEC 60320 C20 4 x IEC 60320 C19, 20 x IEC 60320 C13 230 V AC 0U Vertical Rack Mount TAA C Eaton PDUMV20HVNETLX PDU - Tripp Lite by 3.7kW Single Phase Switched LX Interface 208/230V Outlets (20 C13 & 4 C19) C20/L6 20P 0U TAA Switched NEMA L6 20P, IEC 60320 C20 4 x IEC 60320 C19, 20 x IEC 60320 C13 230 V AC 0U Vertical Rack Mount TAA C Eaton PDUMV20HVNETLX PDU - Tripp Lite by 3.7kW Single Phase Switched LX Interface 208/230V Outlets (20 C13 & 4 C19) C20/L6 20P 0U TAA Switched NEMA L6 20P, IEC 60320 C20 4 x IEC 60320 C19, 20 x IEC 60320 C13 230 V AC 0U Vertical Rack Mount TAA C

Eaton PDUMV20HVNETLX PDU - Tripp Lite by 3.7kW Single Phase Switched LX Interface 208/230V Outlets (20 C13 & 4 C19) C20/L6 20P 0U TAA Switched NEMA L6 20P, IEC 60320 C20 4 x IEC 60320 C19, 20 x IEC 60320 C13 230 V AC 0U Vertical Rack Mount TAA C

The PDUMV20HVNETLX 3.2-3.8kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 24 switched outlets (20 C13 and 4 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-foot cord with NEMA L6-20P plug connects the PDU's C20 inlet to a compatible AC power source, generator or protected UPS.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A digital ammeter allows you to monitor each bank's load in real time to ensure it remains well below maximum capacity with no danger of overload. The vertical PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.

More from the Manufacturer

Manufacturer: TRIPP LITE SUPPORT
MPN: PDUMV20HVNETLX
Availability: In stock
Condition: New
$996.83
Add to Wishlist

Product Description

Technical Information
  • PDU Type:
    Switched
  • Phase:
    Single Phase
  • Plug/Connector Type:
    NEMA L6-20P, IEC 60320 C20
  • Receptacle Type:
    IEC 60320 C19, IEC 60320 C13
  • Receptacle Detail:
    4 x IEC 60320 C19, 20 x IEC 60320 C13
Power Description
  • Input Voltage:
    230 V AC
  • Input Voltage Range:
    200 V AC - 240 V AC
  • Output Voltage:
    230 V AC
  • Power Rating (Watt):
    3800 W
  • Input Current:
    20 A
Management
  • Management:

    Protocols:
      • HTTP
      • HTTPS
      • SMTP
      • SNMPv1
      • SNMPv2
      • SNMPv3
      • telnet
      • SSH
      • FTP
      • DHCP
      • NTP

Physical Characteristics
  • Mounting Orientation:
    Vertical
  • Mount Type:
    Rack-mountable
  • Rack Height:
    0U
  • Height:
    70"
  • Width:
    2.2"
  • Depth:
    2.6"
  • Weight (Approximate):
    8.50 lb
Miscellaneous
  • Country of Origin:
    Taiwan
  • TAA Compliant:
    Yes
  • Environmentally Friendly:
    Yes
  • Environmental Compliance:
    Restriction of Hazardous Substances (RoHS)

OVERVIEW
PDU Type:Switched
OUTPUT
Output Capacity Details:3.84kW (240V), 3.68kW (230V), 3.52kW (220V), 3.33kW (208V), 3.2kW (200V) / 16A total capacity 16A max per C19 outlet 12A (10A CE) max per C13 outlet
Frequency Compatibility:50 / 60 Hz
Output Receptacles:(20) C13 (4) C19
Output Nominal Voltage:200 208 220 230 240
Overload Protection:n/a
Customized Load Management Receptacles:Each outlet is individually controllable via remote interface
INPUT
PDU Input Voltage:200 208 220 230 240
Recommended Electrical Service:20A 208/240V 16A 230V
Maximum Input Amps:20
Maximum Input Amps Details:Agency de-rated to 16A continuous
Input Connection Type:C20 inlet accepts included L6-20P input cable
PDU Plug Type:NEMA L6-20P IEC-320 C20
Input Cord Length (m):3.05
Input Phase:Single-Phase
USER INTERFACE, ALERTS and CONTROLS
Front Panel LCD Display:Digital meter reports PDU output current in amps
Front Panel LEDs:24 power availability LEDs confirm power off/on status for each built-in outlet
PHYSICAL
Form Factors Supported:0U vertical rackmount includes rackmount brackets. Supports toolless mounting in button-mount compatible racks
PDU Form Factor:0U Vertical
ENVIRONMENTAL
Storage Temperature Range:5 to 140F (-15 to 60C)
Relative Humidity:Up to 95% non-condensing
Operating Elevation (ft.):Up to 10,000
Operating Elevation (m):Up to 3000
COMMUNICATIONS
SNMP Compatibility:Built-in LX Platform Interface
CERTIFICATIONS
Certifications:Tested to UL 60950-1:2007 (USA), CAN/CSA-C22.2 NO. 60950-1-07 (Canada), IEC 60950-1: 2005 (CE), FCC Class A, EN55022:2010+2011, EN55024:2010 (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
Item Dimension (L inchxW inchxH inch)
73 x 7 x 6
Weight
19.00lb
Warranty Information
2-year limited warranty